A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
Today you will learn about "how to control a single phase submersible pump motor" or how to control single phase motor from two points. In this type of controlling we used the two magnetic contactor and two double pole mcb circuit breakers (Miniature Circuit Breakers), two normal open push button switches and 2 normal open push button switches.

How to control single phase motor from two places


The motor will control from two places, in which the first place supply will come from the Main kWh Energy meter and for 2nd place the supply comes from kWh check meter or 2nd energy meter.
Here I explain the complete controlling and wiring diagram step by step. In this type of connection a single phase motor used under two householders in which one owner of houses and the 2nd are people who take the 2nd house on rent.

So the motor can be on/off from both places. For that we can do connection as I shown in the below diagram.

how to control single phase motor from two points


In the above how to control single phase motor from two points diagram the first energy meter supply goes to first MCB circuit breaker and kWh check meter. From the kWh check meter the supply goes to the 2nd double pole MCB circuit breaker.

From the first double pole mcb circuit breaker the supply goes to the first contactor and to contactor push button switches or on/off the motor. But here we do an interlock system. In which if the motor start from first contactor then no one can start it from the second place (contactor) in same time. And when the motor switch off from first place then the 2nd person can on/off the motor from second places. But if motor start from the second place then no one can on/off the motor from the first place.

The same connection done with same contactor, the supply comes from the double pole mcb circuit breaker and connect to the contactor. And from there the supply goes to the on/off motor push button swathes. (The start button shown with green color and red button shown as motor OFF button).

The motor output supply is take from the output terminals of contactor and from there the supply goes to the motor as shown in the above diagram. The both output supply are connect together in which the output neutral wire from the first contactor is connected with 2nd contactor output neutral wire and then neutral wire goes to the motor. And same done with Phase (Line) wire.  If you want to learn about the single phase submersible pump starter wiring diagram the read the below guide...

Read Also:
Single Phase Submersible Pump Stater Wiring Diagram

I hope this single phase motor controlling from the two places diagram (how to control single phase motor from two points) help you. If you have any question then you can ask me in the below commenting box.
Note that this diagram is just from information and learning. Don’t try this type of connection in your home himself, and for doing this type of connection call a professional. Stay tune with us and take care…..

A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
As we know that we use magnetic contactor for many types of controlling systems, in this post you will watch a magnetic contactor animation diagram. In the magnetic contactor working animation diagram, you will see the internal working structure of a magnetic contactor. In the contactor animation diagram, the contactor internal main contacts and auxiliary contacts are shown. Here you can see the contactor animation diagram part 1.


magnetic contactor animation diagram




















In the above magnetic contactor internal structure diagram, the main contacts, iron core, coil, and

auxiliary contacts are shown.

This is the first part of magnetic contactor animation diagram, now let's move to the Second diagram. In the below magnetic contactor animation diagram is shown that the magnetic contactor coil are energized and the motor/load is start.


magnetic contactor animation


Now I hope the above magnetic contactor animation diagram help you to understand the working principle of a magnetic conductor. And after this diagram now you will be fully understood that how a magnetic contactor works. Now if you have any questions regarding this contactor animation wiring diagram then you can easily submit your question in the below comments box.

Also Read:
What is Magnetic Contactor?
What is auxiliary contacts in magnetic contactor?
How to wire a contactor for 3 phase motor
How to wire contactor for single phase motor
Direct online stater animation diagram
A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
For low load three phase motor we use direct online starter for controlling. But how a direct online works and how to wire a direct online starter for a 3 phase motor. In this post you will learn DOL starter with simple direct online starter animation. The diagram is complete animated and simple to understand. And this not a single animation, we divide it in parts. In first part i shown that the motor is OFF, and 2nd part i shown that motor is ON and in last the motor is OFF. The all process is shown with simple animation diagrams.


Direct Online Starter Animation Diagrams - DOL Stater Animation


Before we talk about the diagram first we talk about the magnetic contactor, thermal over current protection relay, normally close push button switch, normally open push button switch. In the diagram the contactor which is used is 380 to 440 ACV. A thermal overload relay is used for protection during the over current flow to motor. (In thermal overload relay the NC and NO contacts shown) A red normally close push button switch shown and normally open push button shown.

In the direct online starter animation diagram a 3 phase 440 volts supply is shown which is connect to the magnetic contactor main contacts. From the blue wire  a wire goes to the thermal overload relay normally close contacts and from there the wire goes to the contactor coil A1 terminal.


From the red line wire a wire goes to the normally close push button switch. From the NC push button switch the wire goes to normally open push button input terminals and from same place a wire goes to the normally open auxiliary contacts of contactor. This wire will called hold wire.

From the NO switch output terminals a wire goes to other side of NO auxiliary contacts of contactor and from same point the wire goes the contactor coil A2 terminal. This wire will called touch wire in simple words.


Here is the first look of 3 phase motor direct online starter wiring animation diagram in which the motor is not start.



direct online starter animation

In the above animation diagram. I show that motor is not start and NO push button switch in normal state. Now in next step the normally open push button switch is ON and the motor is also ON.
As you know that we use normally open push button switch only for touch current or starting time current.

motor control animation
In the above 3 phase motor controlling diagram the normally open switch is in close state, in the next diagram the normally open switch is open state but motor is start because the other line wire goes to contactor in hold wire through the contactor normally open contacts (because now contactor normally open auxiliary contacts is close).
3 phase motor wiring animation
Now if we want to switch off the motor, then we need to push normally close push button switch and when we push the normally close push button switch. The supply which goes to contactor through the hold wire (blue wire from normally open switch) with cut and magnetic contactor will be De energizing. As I shown in the below direct online starter animation diagram.
three phase dol starter wiring diagram

Now after pushing the red push button switch (NC switch) the circuit will turn normal state as I shown in first diagram.

I hope after this direct online starter animation diagram, now you will be able to wire direct online starter (DOL starter) for a three phase motor. Now if you have any question in above 3 phase motor wiring animation diagram then you can ask your question using the commenting system.

A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
14 pin relay is numbering in top using electromagnetic relay that's why this post is about the " 14 pin relay connection diagram ". As you know that in the "14 pin finder type relay" we have the 14 connection or terminals which are named or numbered form 1 to 14. This relay used in many circuits. In the relay we have 14 pin in which some are for relay coil supply, some are common, some are normally close circuit with common pins and some are normally open. But what the real shape of it's connection diagram. This post is about the 14 pin relay connection diagram which cleared that which terminals are common, NC , NO etc.

14 Pin Relay Connection Diagram - 14 Pin Relay Wiring Diagram


In the "14 pin relay" we have 14 pin and mostly the 14 pin relay connection diagram is available on the relay body. However i design it very clear to understand.

In the 14 pin relay :

No 13 and 14 pin are for relay operating coil
No 1,2,3,4 are normally close with common terminals
No 5,6,7,8 are normally open with common terminals
No 9,10,11,12 are common terminals,


In Which :
No 1 is normally close with no 9 pin and no 5 pin / terminal is normally open with no 9 pin.
No 2 is normally close with no 10 pin and no 6 pin / terminal is normally open with no 10 pin.
No 3 is normally close with no 11 pin and no 7 pin / terminal is normally open with no 11 pin.
No 4 is normally close with no 11 pin and no 8 pin / terminal is normally open with no 11 pin.


Here i shown the the 14 pin relay connection diagram or 14 pin finder relay wiring diagram. Note that with 14 pin relay we use the base or relay socket. In which the relay installed or inserted.

14 pin relay connection diagram


If you want to learn about the 14 pin finder relay base wiring diagram then visit the below link

Also Read:
14 pin relay base wiring diagram

14 pin relay mostly used for small load controlling in circuits. However this post is only about the basic 14 pin relay connection diagram and further we will use in many circuits. So stay tune with us.
A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
In Controlling relays "14 pin relay" is numbering in those electromagnetic relays which we use in many circuit. In this post I am sharing a the 14 pin relay base wiring diagram. With 14 pin relay we use the base or relay socket in which the relay is inserted. In the 14 pin relay we have 14 pin or connection terminals in which the 4 terminals is common terminals, 4 terminals are N.C (normally closed) with common terminals, 4 terminals are N.O (normally open) with common terminals and 2 terminals for relay operating coils. This relay we use for different type of controlling circuits.

14 Pin Relay Base Wiring Diagram - Finder 14 Pin Relay Socket Diagram


In this post you will learn about the 14 pin relay base wiring diagram. On the relay we have the wiring diagram in which all terminals shown with its working principles.


As I said above that in relay we have 14 pin which is numbered form 1 to 14.
In which :

13 and 14 are for relay coil
9 is NC with 1 and NO with 5
10 is NC with 2 and NO with 6
11 is NC with 3 and NO with 7
12 is NC with 4 and NO with 8


In the below I shown the 14 pin relay wiring diagram with 14 pin relay base. This is also the 14 pin relay base wiring diagram.

14 pin relay base wiring diagram


In the above 14 pin relay base wiring diagram or socket wiring diagram. I shown the 14 pin relay and it's terminals with numbers. Then I shown the bottom view of 14 pin relay and then 14 pin relay wiring diagram. The relay base will be wire according the relay. For example in relay we have 14 and 13 number terminals for relay operating coil. So in the base the 13 and 14 number terminals are for relay coil. Note that this relay can be different according the rated voltage and power source type. Mostly this relay available is market in DCV 12, DCV 24, ACV 220 Volts and much more. And mostly design for 5 Ampere load controlling.

Also Read

Digital Multi Voltmeter Ammeter Hz Wiring With Diagram

This post is only about the 14 pin relay basic wiring diagram. In next post we will use in different circuit for different type of controlling. I hope this 14 pin relay base wiring diagram and relay wiring diagram help you to use this relay in circuits.
A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
In three phase power system, we wire and install the voltmeter to measure the AC voltage, in this post you will learn about the 3 phase voltmeter connection diagram for a digital voltmeter. I already published posts about the three phase volt meter wiring / installation. Also the volt meter selector switch wiring diagram / installation for 3 phase and also for three phase 4 wire system. In his post I am going to write about the three phase digital voltmeter wiring for single phase and 3 phase, but I only share the diagram about the 3 phase digital panel voltmeter, in which I use it for line to line voltage measurement.

3 Phase Voltmeter Connection Diagram For Line To Line Voltage Testing (440V)


In a 3 phase analog voltage meter we have 2 terminals or contacts to provide the supply. We can connect our single phase (neutral and Phase) to these connects or connection point to measure the voltage between neutral and phase. But as you know that meter is design for three phase system (0 to 500 volts) so always use it for measurement voltage between line to line (phase to phase).

So we connect two lines (i.e. L1 and L2) to analog voltage meter to measure the voltage between Line 1 to Line 2. But in digital we have some different connection and we also required the neutral or we can said if we are going to install a digital voltmeter to measure voltage between line to line then we also required the neutral to operate digital volt meter.

In digital voltmeter we have two types of input contacts, one for to operate digital V meter or to operate the display of meter. The 2nd input for voltage to measure. Here I had shown a diagram in which I wire the voltmeter for measuring voltage between L1 and L2.


3 phase voltmeter connection diagram



In above digital 3 phase voltmeter connection diagram. I shown the neutral and phase supply goes to 6 and 8 terminals for voltage meter which is for operating the display. As the L1 is connected to the 6 number terminal and this is also line than a wire connection will goes from this point to 2 number terminal.



The 1 and 2 number points are for input AC supply to measure. So we connect the L1 to the 2 number and the L2 wire to 1 terminal.

The above connection for digital voltage meter is for line to line voltage testing. However if you want to wire it for single phase (Neutral to Phase) voltage testing then provide also the single phase 220 supply to the 1 and 2 terminals.

Note the connection diagram can be different for different model of voltmeters. It's depends on company who manufacture the voltmeters. So this is just an example of wring connection. It's incoming supply for display and terminals number can be different in different model of voltmeter. So the better option is that to read the provide guide or diagram of voltmeter and which is provided on side or back side of voltmeter. Here is the above voltmeter example.....

digital panel meter 0-500v connection



In the above image the voltmeter connection method shown. In which High and Low for input AC supply voltage testing. Note this meter can test voltage from 0 to 500v. In the above diagram AC power terminals are 6 , 7, 8 but in meter only 6 and 8 number contacts available which for 220 volts. However if the 110 V option available and your supply is 110v the connect you supply to 0v and 110v contacts.

(Note every voltmeter have their own diagram and their own connection. So this is not important that the connection name and number are same. Or the connection method is same. So always read the digital meter contacts diagram and then wire it)

Also read
I hope this post help you to understand the 3 phase voltmeter connection diagram or how to wire / install a digital panel type voltage meter for single phase (220 v) or double line voltage testing (440v).
A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
Mostly in electrical technology students , a question are serve in his minds about the single phase motor that how to identify starting and running winding. Basically when we talk about the single phase motor wiring or installation connection. We always think about the start , run and common wire or terminals. In one phase motor connection we have three wire are coming from the motor winding which are start , run and common. As you know that we have two types of winding in a single phase motor which we known with name of starting and running winding. The running winding also called the main winding while the starting winding is better known with name of "auxiliary winding". The point where these moth winding are connected is called the common point which we know better with name of "common connection of a one phase motor" or "the common terminal of a single phase refrigerator compressor".


how to identify starting and running winding


How to Identify starting and running winding in a single phase motor

If you open the single phase motor , you will find out that your motor have two types of winding in which one is made from thick wire gauge and one thin . the thick wire gauge winding is main winding and thin wire gauge winding is starting winding. But this Identification can be done when you open the motor but what you will do if don't want the motor and just want to find out starting and running winding from the main connection plate or connection point.
(Basically to identify starting and running winding is just to find out the start , run and common connection.)

In a single phase motor we have three wires which comes from the both stating and running winding. Which we known with the name of common, start and run connection. To find out the common , start and run wires or connection first read the connection plate diagram and notes to find out which one is common, which one is running and starting. In some one phase motor the the common wire come with black color wire, run as red and start as white color. But this is not important that the connection will come with same colors. Mostly  these color are change. So the better and easy option to to find out the run , start and common wire or connection to read the connection plate diagram or chart. And if you did not find any guide about the connection then follow the below step.


Use a Multi meter You can easily identify the common , starting and running connection of a single phase motor. In the single phase 3 wire motor we have a high resistance between the start and run connection or wire. And if you find out that two wires have a high number of resistance showing on multi meter or ohm meter in three wire then it's means that these two wire are start and run connection and the other one is common. However to complete understand , fallow the below step by step guide


  • First of all set your multimeter on ohm testing 
  • Then check resistance between wire to wire in 3 wires
  • If you find out that two wire have greater resistance between one another then it's mean that these are start and run and the 3rd one is common.
  • So you identify the common wire , so the next step to find out which one is start and run wire.
  • The method is easy, the resistance between common and staring will greater then the Resistance between common and run wire. So the greater resistance between common and other wire will identify that this is start , starting connection or terminal. So you find out that starting connection. So it's clear the other wire is run connection wire.

To identifying starting and running winding' i means that you are searching about the staring and running and common identification in a single phase motor. So if you are searching for this then the above method is for you. And if you want to identify the starting and running winding then the easy method to open the motor internally. And see which winding wire greater in size. For example is you find out two winding and one winding are made from 21 SWG and 2nd winding is made from 26 Then 21 SWG is greater in size which running winding or main winding and 26 SWG winding is staring or auxiliary winding. 

(Note That the above start, run and common identification method you can use for any single phase induction motor, like ceiling fan, single phase submersible water pump motor, for A/C outdoor coiling fan etc.)

I hope this post help you find out how to identify staring and running winding or identification the start, run and common terminals or connection is a single phase motor. If the post help you then kindly share this post. And if you have any question then you can use the below comment section for asking you question. I will try my best to gave answer of your comments.
A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
As you know that we start from the basic steps. In this post I am writing about 3 phase manual changeover switch wiring diagram or three phase manual transfer switch wiring diagram. As you know that I already published a post and diagram about the manual changeover switch wiring diagram (single phase) with complete installation and wiring connection method. In Today post I am here to write and share a diagram about the three phase manual changeover switch wiring diagram and it's installation with incoming supply from the main supply, incoming supply from the 3 phase generator and outgoing supply to the three phase load. Note that this diagram is about the manual handle type change over switch and IN SHA ALLAH soon I will make a diagram about the rotary type change over switch wiring diagram for single phase, three phases and three phase four wire system.


3 Phase Manual Changeover Switch Wiring Diagram For Generator With Complete Installation Guide


The 3 phase manual changeover switch wiring diagram is too simple and easy connection. For better understanding kindly read the below single phase handle type manual transfer switch post.

Also read

How to wire and install the manual transfer switch for single phase

The three phase changeover wiring connection and installation is too simple and easy connection as I shown in the below diagram. In the below diagram I shown the incoming 3 lines supply wires with read red, yellow and blue colors. The neutral I shown with black color but the neutral- is not used in the three phase manual transfer or changeover switch. The main supply is connected to the switch upper input supply terminals. And the generator supply connected to the bottom- input terminals or connection points of transfer switch as I shown in the below diagram. The output supply is goes to load from output connection points or terminals. I have shown load as three phase induction motor. One thing more if we move the switch handle upper side, the main supply will goes to the load. When we move the transfer switch handle to center-, the switch will on OFF mode. And when we required the generator emergency supply for load then we move the changeover handle to bottom- side.


3 phase manual changeover switch wiring diagram



(Note that this type of switch we use in our country, may be the type or shape will be different as I shown in the diagram but the reason- of publishing this post is that to tech you about the basic working principles- of a transfer or three phase manual changeover switch)

I hope after the above 3 phase manual changeover switch wiring diagram, now you will be complete understood. However you can ask you question according this diagram or post then you can use the below commenting system.
A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
Today I am writing about the refrigerator overload protector testing using multi meter. In this post I will complete guide you about how to test a refrigerator thermal overload protector using a multimeter. As you know that thermal overload protector is designed to protect the refrigerator compressor during over current flow. I also published a post about working principles of refrigerator compressor thermal overload protector. The overload protector is connected near with the starting relay of the compressor, and connects to the compressor common terminal. When the thermal overload protector heat up or make an open connection internally the compressor stop running. The working of thermal protector is that to stop the electric supply during the over current flow to compressor or when the compressor become heat up. Some time when ref compressor become heat up the thermal overload protector stop the electric supply to the compressor to protect the compressor winding from the burning. To learn more about the working of refrigerator thermal overload protector click here.


Also Read
How a overload protector works
How a ptc realy works 
How to test and wire refrigeator thermal thermostat switch

How To Test Refrigerator Overload Protector Using Multimeter


  • The refrigerator overload protector testing is very easy using a multi meter, to test your refrigerator thermal overload protector follow the below steps.
  • First of all off the refrigerator and plug out the refrigerator supply plug from the outlet, or switch off the double pole circuit breaker from which the refrigerator supply plug controlled.
  • The thermal overload protector is connected or install near with the starting (PTC relay) with compressor terminals. Just remove the relay from the compressor and then remove the compressor overload protector.
  • Remove the both wires from the thermal overload protector.
  • Then set you multi meter on connectivity test or diode testing. Connect one testing lead to one terminal of the thermal overload protector and other testing lead to the other terminal of compressor overload.
  • If you find that there are some connectivity then its means that the overload is alright and working properly. And you don't need to replace the overload.
  • And if you don't see any connectivity then waits 5 to 10 minutes and then tests the thermal overload protector again. And if still has no connectivity then its means that your refrigerator overload is internally open connection or cut. And you must change the overload protector with new one with same range.

Refrigerator Overload Protector Testing Using Multi-meter


Here I try to make you understood using simple refrigerator overload protector testing troubleshooting diagram. In the below diagram I shown an Analog multi meter which set on the connectivity test, ohm test (resistance testing). And I connect the one testing lead to one terminal of overload and other testing lead to other terminal of the overload. In diagram I shown that multi meter shown no reading or no connectivity which means that the overload is not working or internally open.

Refrigerator Overload Protector Testing


In the below 2nd fridge thermal overload protector testing troubleshooting diagram. I shown that millimeter shown the reading and shown connectivity between two points which means that overload is working properly and no need to change.

How To Test Refrigerator Overload Protector



In the above diagram I shown and clear that if the refrigerator thermal overload protector have connectivity between two points then its means that overload is working fine. But some time if an overload is not tripping or not make an open circuit during over current flow to the compressor then this overload is not a good overload. So the proper method to test your overload compressor starting time and running time current (ampere) and if the overload is not opening circuit during the over current flow then change the overload protector.


Now if the overload is internally open circuit then change and if it's have a connectivity between both terminals of overload then test other common places and problems of refrigerator not working. I hope by reading this refrigerator overload protector testing guide, now you will be able to test the fridge thermal overload protector. Be safe and follow all safety rolls before start testing or replacing the thermal overload protector to refrigerator compressor.
A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
Today I am here to share with you the 3 phase submersible pump wiring diagram. In which I control a three phase submersible pump motor using magnetic contactor. Not only a contactor but also I install the thermal overload relay which will protect the motor form burning in case of over current flow to the circuit. In the diagram I showed the 3 Pole MCCB breaker, magnetic contactor , thermal overload protection relay, and normally open, normally close push button switches. 3 phase submersible pump motor and electric wiring connection. This will be the complete guide of controlling a three phase submersible pump motor using magnetic contactor.

3 Phase Submersible Pump Wiring Diagram Explanation Complete Guide


Before I explain the diagram. I want to write about the device and things in this circuit. In Circuit first we use the MCCB breaker. (Module Case Circuit Breaker)
We used a three pole MCCB circuit breaker in the diagram. This circuit breaker will control the all substances use in the circuit and we can switch on/off the electric power supply by using the three pole circuit breaker. In the diagram I did not control the neutral wire. However if you want to control the neutral (N) black wire then you must use the 4 pole circuit breaker.

The next thing which used in the circuit is the magnetic contactor. Basically a contactor is a type of relay which we can use for different works. However if you want to learn more about the magnetic contactor basic explanation then the below guide is for you.

Also read:

The push button switches which used in the circuit is NC and NO switches. The normally open contacts switch will be use for starting the motor. And normally close contacts push button switch will be used for switch off the motor or load.


The next device which use in the below 3 phase submersible pump wiring diagram is a thermal overload relay. Which we use to protect or switch off the motor or load during over current flow. This device is available in different shapes and different values according load. In thermal overload protector we have move able ampere adjustable. From which we can setup the ampere or load level.





Now come to the wiring connection of three phase submersible pump. This wiring connection is too simple just like our old diagram. In which I showed the three phase motor controlled using contactor and overload relay. You can also read and see the diagram by using the below link.


Three phase submersible Pump Wiring Diagram with direct online starter


First see the 3 phase submersible pump wiring diagram and after that I will explain each step of below connection diagram.




3 Phase Submersible Pump Wiring Diagram
Three Phase Submersible Pump Wiring Diagram


In the above diagram I showed the L1 L2 L3 and N wire incoming supply with red, yellow, blue and black. In which the red, yellow and blue for 3 phases and black color wire for neutral.


The incoming supply goes to MCCB circuit breaker. I shown the three poles MCCB breaker which is for controlling the three phase power supply and you can switch ON/OFF by using the circuit breaker. Then neutral wire is direct and if you want to control the neutral wire then uses the 4 pole circuit breaker.
In the above diagram I shown the magnetic contactor which I also explain, the magnetic contactor wired after the circuit breaker. Click here to learn about magnetic contactor.
After condactor, they connection done between the contactor load main contacts and thermal overload relay main input terminals.
Phase wire connections comes from the MCCB output terminals and connected to NC push button switch and then from the normally close switch, this connection goes to the magnetic auxiliary normally open contacts. And to the normally open switch. From the normally open switch wire will gees to the other side of normally open auxiliary contact and to the stater coil.
The neutral wire connected to the normally close contact of thermal overload relay. And form the other side of thermal overload relay normally close contact wire goes to the other terminal of magnetic contactor coil.
In last does the connection of 3 phase motor or three phase submersible pump to the thermal overload relay main terminals.
Also do the earth wire connection to panel box and to the motor.

I hope now you will be understood, however if you have any question according the 3 phase submersible pump wiring diagram. You can ask your question according to the three phase submersible pump wiring diagram in the below comment section. One thing more the above diagram and text in only for information base and in case of wrong connection done or if we do any mistake by creating this post or diagram, and due any wrong connection done we will not be liable for any losses. For more read our privacy and policy.

A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
Today i am writing about manual changeover switch wiring diagram , as you know that we use generator as emergency power source in our house wiring , we can do the generator changeover system in two methods, in which one is manual and 2nd one automatic system. This post is about the manual changeover switch wiring diagram for portable generator, and IN SHAA ALLAH  we also write and make diagram about the automatic changeover switch wiring which we known better with the name of the ATS system. (Automatic transfer switch)


Electrical Manual Changeover Switch Wiring Diagram For Portable Generator


Manual changeover switch are mostly use in 2 types , in which one have the move able knob and 2nd one the handle changeover switch. This post i will shown the complete method of manual or handle change over switch , the knob type manual changeover switch wiring same like handle change over switch and it's just like a voltmeter sector switch.


Last day i am doing some new electrical instillation, and i saw the handle type manual changeover switch, and get a photo for you, which help you in understanding the connection. Note this post is only about handle type manual changeover switch wiring diagram , however the knob type changeover connection is also same.

There are 3 types of changeover switches which we use for generator and main supply or we can also use the changeover switches for two supplies. 

⇒ Type one : which we use for single phase supply, and for single phase generator
⇒ Type two : which we use for 3 phase power supply and generator
⇒ Type three : which we use for 3 phase 4 wire system and generator

In this post i am explaining the type one , Below i shown the single phase manual changeover switch with image and connection & manual changeover switch wiring diagram with complete connection of  main supply and generator supply and out going supply to the load.



manual changeover switch wiring diagram



In the above manual changeover switch wiring diagram , i shown the incoming supply from the energy meter, incoming supply form the portable generator , and out going supply to load or house load.

In the diagram i shown handle type manual changeover switch. in which i done all the connection. On thing more always do earthing connection to the changeover body , if you have the earth wire. This connection can also work with out the earth or ground connection, But in Electrical Works the most important thing is safety so always do ground connection.
In the above diagram the black color denote the neutral wire , red color denote the phase wire (Line / Hot wire) and Green color denote the earth / ground wire.

After this diagram i hope now you will be able to connect a portable generator to house load. here i have an image of  handle type manual changeover switch which capture with my mobile camera.


manual changeover switch

In the above manual changeover switch / transfer switch image, the connection is not done, and not a proper method of installation and wiring, however i capture this image just for you to see the manual changeover switch / transfer switch internally. I hope after the above image and manual changeover switch wiring diagram, now you will be able to connect a portable generator to your house wiring. IN SHAA ALLAH soon i will make a diagram about connection of portable generator to distribution board or how to connect your portable generator to your distribution board.

A platform to learn electrical wiring, single phase, 3 phase wiring, controlling, HVAC, electrical installation, electrical diagrams.
Today i am wiring about the rcd wiring installation in single phase distribution board. as you know that we always focus on safety and protection in electrical works. And that's because of that electrical works and electrical wiring is more than dangerous from other works. Always safety first in every work.
RCD are available in many types but fixed RCD (residual current device) are number one device to make a great protection in electrical single phase wiring installation.

RCD Wiring Installation In Single Phase Distribution Board


The wiring installation of rcd is very simple in main distribution board, you need to connect the fixed RCD after the main two pole circuit breaker. Here is the rcd wiring diagram in which i install the main distribution board.

rcd wiring diagram in distribution board


In the above distribution diagram i shown the wiring installation of Double pole MCB circuit breaker , rcd circuit breaker, single pole mcb breakers, voltmeter, light indicator. The installation of rcd is too simple in single phase wiring main board.
You need to connect the rcd or do connection of residual current device after the double pole mcb main circuit breaker as i shown in the above diagram.
However lets explain the complete installation of complete main DB board. you need to fallow these steps.

  • First you need to get supply from the main double pole circuit breaker and connect to the rcd fixed rcd breaker as i shown in the above rcd wiring diagram.
  • Now get Hot wire (phase) from the rcd breaker and connect to all one pole mcb breakers and neutral to neutral bus bar as i shown in the above rcd diagram.
  • For wiring of voltmeter and indicator you need to connect the phase supply from the breaker and neutral wire to neutral connection point.
  • The earth connection is connected in the bus bar , or earth connection point.
  • In last you need to get supply from the neutral point and earth point and from circuit breaker for different loads.
In the above rcd wiring installation diagram i shown the incoming supply (N and L). The rcd wiring is too simple and easy connection, however here some other tutorials which help you more to understand it easily.

Also read

I hope after reading this post and rcd wiring diagram, you will be completely understood. However now if you have any question regarding this post or rcd wiring diagram then you can ask me by using the below comment section.